PPWR Compliance Services
PPWR Testing: Recyclability Assessment, PFAS Analysis and Accredited Laboratories
PPWR testing since 12 August 2026: PFAS and heavy-metal analysis, recyclability assessment, accredited labs (Art. 36) and why no PPWR certificate exists.
PPWR testing is the laboratory analysis, measurement and calculation that a manufacturer uses to show that its packaging meets the requirements of Articles 5 to 12 of Regulation (EU) 2025/40, which applies since 12 August 2026. No test is mandatory in itself and no laboratory can certify packaging: the manufacturer declares conformity on its sole responsibility (Annex VII point 1).
Article 35 of the PPWR requires every test, measurement and calculation for Articles 5 to 12, 24 and 26 to use reliable, accurate and reproducible methods. The methods take generally recognised state-of-the-art methods into account and give results of low uncertainty.
The results are filed as test reports (Annex VII point 2(f)). Those reports belong to the technical documentation that the EU Packaging and Packaging Waste Regulation (PPWR) requires for each packaging type.
The Regulation prescribes no single test, and Annex VII lists test reports only "wherever applicable". Which tests apply depends on the packaging: PFAS limits cover food-contact packaging, the heavy-metal sum covers all packaging, and recyclability and recycled content wait for Commission acts.
Compiled by the PackagingRegulation.org Editorial Team from the Regulation's text on EUR-Lex and the cited official sources. Every article reference on this page is checked against the Official Journal; see our methodology and fact-checking.
What Does PPWR Testing Cover?
PPWR testing covers every requirement of Articles 5 to 12, 24 and 26 for which a test, measurement or calculation is made, and Article 35 of the PPWR requires reliable, accurate and reproducible methods for all of them. The table lists six requirements with their dates.
| Requirement | PPWR basis | What a laboratory measures or assesses | Applies from |
|---|---|---|---|
| PFAS in food-contact packaging | Art. 5(5) | Total fluorine and targeted PFAS analysis against 25 ppb, 250 ppb and 50 ppm | 12 August 2026 |
| Heavy-metal sum | Art. 5(4) | Lead, cadmium, mercury and hexavalent chromium, sum not above 100 mg/kg, all packaging; carried over from Directive 94/62/EC | 12 August 2026 |
| Recyclability | Art. 6(2), 6(4) | Design-for-recycling assessment per packaging unit once the delegated acts exist | 1 January 2030 or 24 months after the Art. 6(4) acts, whichever is later |
| Recycled content (plastic) | Art. 7(1), 7(8) | Calculation and verification under the pending implementing act | 1 January 2030 or 3 years after the Art. 7(8) act, whichever is later |
| Minimisation | Art. 10(4)(c) | Tests, studies, modelling and simulations for the documentation | 1 January 2030 |
| Empty space ratio | Art. 24(1), 24(2) | Measurement under the implementing acts due 12 February 2028 | 1 January 2030 or 3 years after those acts, whichever is later |
A laboratory supplies results, and the conformity decision stays with the manufacturer. The manufacturer carries out the Article 38 procedure or has it carried out on its behalf (Art. 15(2)). It stays responsible for placing only conforming packaging on the market (Art. 15(1)).
Is There a PPWR Certificate?
No: conformity assessment under Article 38 of the PPWR follows Annex VII Module A, internal production control, without a notified body, so no laboratory or scheme can issue a PPWR certificate.
Three documents replace a certificate. The Annex VII file lists the standards and specifications used (point 2(d)) and holds the test reports (point 2(f)), and the manufacturer draws up the EU declaration of conformity once compliance is demonstrated (Art. 15(2), Art. 39).
How the file is built is set out under PPWR technical documentation and conformity assessment.
CE marking on packaging does not indicate PPWR compliance (recital 109). Voluntary recyclability certification schemes give no presumption of conformity, which comes only through Articles 36 and 37. The manufacturer keeps the documents for 5 years for single-use and 10 years for reusable packaging (Art. 15(3)), and produces them within 10 days of a reasoned request (Art. 15(10)).
PFAS Analysis: Total Fluorine First, Then Targeted Methods
PFAS analysis for the PPWR checks food-contact packaging against the three limits of Article 5(5), which apply since 12 August 2026, and Commission Notice C/2026/3084 recommends starting with a total fluorine measurement. Packaging placed on the market before 12 August 2026 may stay on the market, and the PFAS limits have no sell-off period.
The Notice (OJ C, 10.6.2026) is non-binding and recommends the three-step sequence below. The Notice states that no harmonised PFAS test method exists at EU level. The limits, the PFAS definition and the scope are explained under PPWR PFAS limits for food-contact packaging.
- Measure total fluorine: a result below 50 mg/kg means the packaging could be considered compliant.
- Above 50 mg/kg total fluorine, use pyrolysis-GC/MS to separate organic from inorganic fluorine: organic fluorine below 50 mg/kg is compliant.
- Run direct TOP analysis for the 25 µg/kg and 250 µg/kg limits.
A further duty sits upstream. If total fluorine exceeds 50 mg/kg, the REACH manufacturer, importer or downstream user must, on request, prove the PFAS and non-PFAS share of the fluorine, so that the manufacturer can draw up the Annex VII documentation (Art. 5(5)(c)).
It is not a fourth limit. The REACH PFAS restriction proposal is a separate procedure.
Which analysis covers the 100 mg/kg heavy-metal sum?
The heavy-metal analysis measures lead, cadmium, mercury and hexavalent chromium, whose sum may not exceed 100 mg/kg in any packaging under Article 5(4) of the PPWR.
The limit is carried over from Directive 94/62/EC. A laboratory reports the four concentrations and their sum for the file. Derogations and the wider substance rules sit with the PPWR substances of concern and the heavy metal limit.
Recyclability Assessment: What a Laboratory Can Assess Today
A PPWR recyclability assessment against grades A, B and C is possible only once the design-for-recycling delegated acts under Article 6(4) exist, which the Commission must adopt by 1 January 2028.
The grades apply from 1 January 2030 or 24 months after those acts, whichever is later, and the assessment is made per packaging unit (Art. 6(4)(b)). Grades, dates and exceptions are explained under the PPWR Article 6 recyclability rules.
Until the acts exist, laboratories and voluntary schemes offer design-for-recycling checks and recycler tests. Their results can inform the qualitative description of the Article 6, 10 and 11 assessments in Annex VII point 2(e). They give no presumption of conformity.
Can a laboratory verify recycled content yet?
Not under a PPWR method yet: the calculation and verification methodology for recycled content in plastic packaging comes from an implementing act under Article 7(8), due by 31 December 2026 and not adopted as of 14 November 2026. No draft of that act has been published on Have Your Say as of the same date.
The methodology may include independent third-party audits of manufacturers of recycled content in the Union and of plastic packaging placed on the market as a separate sales unit (Art. 7(8)). The Article 7(1) percentages apply from 1 January 2030 or 3 years after that act, whichever is later. The percentages per packaging type are listed under the PPWR recycled content targets.
Do You Need an Accredited Laboratory?
No: the PPWR does not require an accredited laboratory, but Article 36(2) links a presumption of conformity to methods performed by conformity assessment bodies accredited under Regulation (EC) No 765/2008.
Article 36(1) presumes that methods conforming with harmonised standards, whose references are published in the Official Journal, conform with Article 35. Article 36(2) applies the presumption to methods "as referred to in paragraph 1" performed by accredited bodies.
Article 36(3) gives packaging the same presumption for Articles 5 to 12, 24 and 26 as the standards cover. Article 37 allows common specifications where standards are missing.
The list of standards and specifications used goes into Annex VII point 2(d), next to the test reports of point 2(f). Which standards and specifications can give that presumption is tracked under PPWR harmonised standards and presumption of conformity.
How to Choose a Laboratory for PPWR Testing
Choosing a laboratory for PPWR testing starts with the requirement to be proven, because a report helps only if its method, scope and sample match what the technical documentation must show.
- Name the requirement and the article the report must cover (Articles 5 to 12, 24 and 26).
- Ask which method is used and whether it reflects generally recognised state-of-the-art methods (Art. 35).
- Check that any accreditation under Regulation (EC) No 765/2008 covers that method, not only the laboratory.
- Agree that the report names the method, sample and packaging unit, so it fits Annex VII point 2(f) and the standards list of point 2(d).
- For food-contact packaging above 50 mg/kg total fluorine, plan the supplier proof under Art. 5(5)(c).
- Plan re-testing for design, material or supplier changes.
Re-testing follows Article 15(4): manufacturers take account of changes in packaging design or characteristics and in the standards and specifications relied on. Where conformity could be affected, they re-assess under Article 38 or have it done on their behalf.
How Does Laboratory Testing Fit the Other PPWR Services?
Laboratory testing is one of several PPWR services: the parent hub on PPWR compliance services compares consultants, authorised representatives and EPR services, and PPWR compliance software keeps the test reports with the packaging data.
The table connects testing with the related pages. Why no laboratory is named here is set out in our editorial policy on provider matching. Food-contact migration testing under the food contact materials rules is a separate legal requirement, and this page covers the EU packaging rule only.
| Page | How it connects to testing | Link |
|---|---|---|
| PPWR compliance services | Parent hub: provider types compared | PPWR compliance services |
| PPWR compliance software | Stores test reports and supplier documents | PPWR compliance software |
| Multi-country packaging EPR compliance services | Registration and reporting, not testing | multi-country packaging EPR compliance services |
| PPWR EU declaration of conformity | States that compliance has been demonstrated (Art. 15(2), 39) | PPWR EU declaration of conformity |
| Recycled content methodology | The Art. 7(8) methodology for calculation and verification | how recycled content is calculated and verified |
| Non-EU manufacturers | Same file; the importer checks it (Art. 18(2)) | PPWR for non-EU exporters |
| Updates | Adoption of the Art. 6(4) and 7(8) acts | PPWR news |
Questions about PPWR testing answered
Is laboratory testing mandatory under the PPWR?
No single test is prescribed: Article 35 requires reliable, accurate and reproducible methods, and Annex VII point 2(f) requires test reports wherever applicable, so the tests follow from which of Articles 5 to 12 apply.
Can test reports from a packaging supplier go into the file?
Yes: suppliers of packaging or packaging materials give the manufacturer all the information and documentation needed to demonstrate conformity, including the Annex VII documentation required under Articles 5 to 11 (Art. 16(1) PPWR). The manufacturer still draws up its own file and declaration (Art. 15(2)).
Does the importer check the manufacturer's test documentation?
Yes: the importer checks that the manufacturer carried out the Article 38 procedure and drew up the Annex VII documentation (Art. 18(2)).